Impedance (Z) is the total opposition to current flow. It is made up of the Resistance (R) and Reactance (X).
Reactance (X) is created by the induced magnetic field around the conductors in the secondary.
Larger K & L lead to increased reactance.
Additionally magnetic material in the form of tooling or the workpiece itself in the throat adds to the reactance and reduces the current flow.
Magnetic tooling or the workpiece in the throat of an AC Resistance Welder
Now look at the Resistance in the welding circuit. The transformer secondary and terminals, secondary conductors in the loop area, electrodes, electrode holders and the workpiece are all components with resistances (R) to current flow. In addition to these conductors each electrical connection has a resistance. The resistances of the conductors and connections in the secondary have to be combined for the total resistance in the system (R).
Impedance (Z) is the square root of the sum of the total resistance (R) and the total reactance (X) squared.
Impedance (Z) is the square root of the sum of the total resistance (R) and the total reactance (X) squared
Lowering impedance will optimize current flow. To accomplish this minimize the throat size. Whenever possible, run insulated conductors and cables close together. Minimize the number of connections. Keep connections clean and tight. Remove magnetic material from in or around the throat area.
Impedance is an inherent factor of AC equipment. DC and MFDC do not have any reactance or magnetic material issues. Therefore reactance is eliminated and only resistance is a factor. Losses are reduced substantially.
Impedance in a DC/MFDC circuit is:
Reference: RWMA Resistance Welding Manual Revised 4th Ed Chapter 19